Be the first to review “Multi-Para Monitor – 7 Para Dr. Diaz (ECG, SpO₂, NIBP, Respiration, Temperature, EtCO₂ and IBP)” Cancel reply
7 Para Monitor on Rent Multi-Para Monitor – 7 Para (Dr. Diaz)
MONITORING SUPPORT – NOT A DIAGNOSTIC OR EMERGENCY-RESPONSE SYSTEMThis Dr. Diaz monitor displays ECG/heart rate, SpO₂/pulse rate, NIBP, impedance respiration, temperature, EtCO₂ (capnography) and invasive blood pressure (IBP).EtCO₂ and IBP should be used only when the treating doctor has prescribed them. EtCO₂ needs a compatible single-use sampling line or airway adapter. IBP needs an arterial or central line, a disposable pressure-transducer kit and trained clinical staff to set up, zero and maintain it.Alarm limits and NIBP intervals must be set for the patient by a qualified clinician. An alarm, abnormal waveform or unexpected value requires assessment of both the patient and sensor placement. The monitor can miss deterioration or generate false alarms and does not replace clinical observation. What’s IncludedPatient Monitor on Rent When Do You Need This?
Home ICU setups where the treating doctor has asked for capnography (EtCO₂) or invasive blood pressure monitoring—for example, ventilated or tracheostomy patients after ICU discharge, with trained nursing staff at home. If only basic vital signs are needed, our 5-parameter monitor is usually sufficient.*Product images are for representational purposes only; actual equipment supplied may vary.*For a clinician-led home-care setup, compare our home-care and hospital essentials, including the Multi-Para Monitor – 5 Para, Cardiac Monitor – 3 Para and ECG Machine, according to the prescribed monitoring or therapy requirement.Families arranging equipment after discharge can use our ICU-discharge home-care checklist.Related planning guide: checks before accepting an alternative medical equipment model.Related planning guide: alarm, noise and caregiver planning for equipment used at night.| Specification | Details |
|---|---|
| Brand | Dr. Diaz (Hemodiaz Lifesciences Pvt. Ltd.) |
| Product type | Seven-parameter bedside patient monitor |
| Parameter 1 | Five-lead ECG waveform and ECG-derived heart rate |
| Parameter 2 | SpO₂ and pulse rate |
| Parameter 3 | NIBP—systolic, diastolic and mean arterial pressure |
| Parameter 4 | Impedance-derived respiration rate |
| Parameter 5 | Temperature |
| Parameter 6 | EtCO₂ (end-tidal carbon dioxide) by capnography |
| Parameter 7 | Invasive blood pressure (IBP) |
| ECG cable | Five-lead patient cable |
| SpO₂ sensor | Reusable adult finger probe |
| Blood-pressure cuff | Reusable adult standard-size NIBP cuff |
| NIBP method | Oscillometric |
| NIBP modes | Manual and automatic interval measurement |
| Respiration method | Thoracic impedance derived through ECG electrodes |
| Temperature sensor | Compatible reusable temperature probe |
| EtCO₂ accessories | Capnography module supplied; single-use sampling line or airway adapter required (not included) |
| IBP accessories | IBP interface cable supplied; disposable pressure-transducer kit and clinician-placed arterial or central line required (not included) |
| Alarms | Configurable audible and visual high/low alarms |
| Technical alerts | ECG lead-off and sensor-disconnection indications |
| Display | Colour display with waveforms, numerical values and alarm status |
| Trend data | Parameter trend storage |
| Power | Mains operation with rechargeable internal battery |
| Battery runtime | Tested and recorded for the exact rental asset before delivery |
| Warranty (purchase) | Manufacturer warranty as per the supplied Dr. Diaz warranty card and terms |
| Diagnostic ECG | No |
| Arrhythmia diagnosis | No |
| Emergency response | Not included |
| Exact model | Manufacturer, model, serial number and enabled parameters confirmed before dispatch |
This equipment is for home patient care only. It must remain at the delivery address registered at the time of order. Relocation requires prior approval from Sanjeevia. Do not attempt to repair or modify any part, contact us for all servicing.
Respiration and EtCO₂:
The respiration rate is derived from changes in chest impedance detected through the ECG electrodes. Movement, poor electrode contact, lead placement and electrical interference can affect the displayed value.
EtCO₂ is measured separately by the capnography module and requires a correctly connected single-use sampling line or airway adapter. Replace sampling lines as per the manufacturer’s instructions and check for kinks, moisture or blockage if readings are unexpected.
IBP safety
IBP must be set up only by trained clinical staff. The arterial or central line, transducer zeroing, levelling and flushing must follow the treating team’s protocol.
Do not use IBP at home without trained nursing supervision. A damped waveform, line disconnection or bleeding at the insertion site requires immediate clinical attention.
Alarm and escalation
Alarm limits must be based on the patient’s clinical plan. Do not use generic adult alarm limits for every patient.
When an alarm activates, first assess the patient. Then check electrode contact, probe position, cuff placement, sampling line, tubing and cables. Do not silence, disable or widen alarm limits simply to stop repeated alarms.
The patient’s care plan must identify which readings or symptoms require contact with the treating team and which require emergency medical assistance.
NIBP safety
Use the correct cuff size and approved limb. Do not place the cuff over wounds, vascular access, an infusion line or another site excluded by the clinical plan.
The clinician must determine whether automatic NIBP measurement is needed and the appropriate interval. Excessively frequent measurements can cause discomfort or circulation problems.
Equipment is cleaned and checked before dispatch. We share a photograph of the actual equipment with you before delivery.
Rental cancellations and early returns
Before dispatch: full refund with no deduction.
After dispatch but before delivery: refund after deducting delivery or logistics charges already incurred.
After delivery: the standard early-return policy applies. Monthly rentals are refunded for complete unused months, and daily rentals for complete unused days. Partial months or days are not refundable.
Delivery and pickup charges are non-refundable once dispatched. If Sanjeevia cancels the order, the customer receives a full refund including applicable transport charges.
In humanitarian cases, refunds are calculated only for complete unused rental periods under the applicable monthly or daily plan.
For Rental
For Purchase
Delivery process
Estimated delivery: Same day for orders placed before 4 PM, subject to availability. Call us directly for urgent requirements.
All sales are final once delivered and confirmed. No refund after delivery.
Wrong product or physical damage on arrival: exchange only, within 48 hours of confirmed delivery. Contact +91 9217910612 or support@sanjeevia.com.
Manufacturer warranty applies- terms vary by brand.
For Rental:
Initiate a return through sanjeevia.com or WhatsApp with your Order ID. We confirm a pickup slot within 4 hours, and rental charging stops when you request pickup.
Early return: Monthly rentals are refunded for each complete unused month. Daily rentals are refunded for each complete unused day. Partial months or days are not refundable.
Delivery and pickup charges are non-refundable once the order has been dispatched.
Equipment condition is checked at pickup against the delivery records. Where no deduction is due after pickup and inspection, online security deposits are refunded within 3–5 business days, and security cheques are returned within 48 hours.
To request an upgrade during a rental, contact us to check same-day replacement availability.
For Purchase:
Purchased equipment is eligible for exchange or replacement only for a wrong product, damage on arrival or a verified defect, subject to the applicable policy terms and legal rights.
Raise an eligible exchange or replacement request within 48 hours of delivery by calling or messaging +91 9217910612, or emailing support@sanjeevia.com.
We assess the reported issue and arrange a replacement at no charge when the wrong product or damage present at delivery is confirmed.
A Dr. Diaz bedside patient monitor displaying seven primary parameters:
The monitor supports continuous observation and configurable alarms. It does not diagnose deterioration, identify the cause of an abnormal reading or replace direct clinical assessment.
EtCO₂ and IBP are advanced parameters for prescribed home-ICU care. IBP requires an arterial or central line placed and managed by trained clinical staff.
Every monitor supplied from this listing must have all seven parameters enabled and must include a five-lead ECG cable, adult SpO₂ probe, adult NIBP cuff, temperature probe, EtCO₂ module and IBP interface cable.
A Dr. Diaz bedside patient monitor displaying seven primary parameters:
The monitor supports continuous observation and configurable alarms. It does not diagnose deterioration, identify the cause of an abnormal reading or replace direct clinical assessment.
EtCO₂ and IBP are advanced parameters for prescribed home-ICU care. IBP requires an arterial or central line placed and managed by trained clinical staff.
Every monitor supplied from this listing must have all seven parameters enabled and must include a five-lead ECG cable, adult SpO₂ probe, adult NIBP cuff, temperature probe, EtCO₂ module and IBP interface cable.
Call us to inquire about the Paramount A5 Bed.
Call to InquireEligibility is checked at checkout. Transport and refundable security deposits are not discounted.
Enter your mobile number so our team can assist if regular rental delivery is unavailable.
For rentals only. Purchased equipment can be couriered across India.
Contact us for a custom plan.
Finding it hard to choose? Our team can help.
I can connect you to our team. I can’t give medical advice. Not for emergencies. Share only information needed for your enquiry.
Optional cookies support analytics and ads. Sanjeevia counts visits with or without analytics cookies. Cookie Policy · Privacy Policy
Choose which cookies to allow.
Keeps the site working, including your cart and checkout.
These cookies are needed for adding comments on this website.
Google reCAPTCHA helps protect websites from spam and abuse by verifying user interactions through challenges.
Google Tag Manager simplifies the management of marketing tags on your website without code changes.
Helps us understand site use so we can improve it.
Google Analytics is a powerful tool that tracks and analyzes website traffic for informed marketing decisions.
Service URL: policies.google.com (opens in a new window)
Clarity is a web analytics service that tracks and reports website traffic.
Service URL: clarity.microsoft.com (opens in a new window)
SourceBuster is used by WooCommerce for order attribution based on user source.
Read our Cookie Policy and Privacy Policy.
Reviews
There are no reviews yet.